09.06.2009

Steam Generator in Austria

Output: 350 kW / Quantity of steam: 540 kg/h

This steam generator is operated at a waste water treatment plant in Austria. The exhaust gas heating the steam generator is provided by two MAN engines (2842 LE). The steam produced is used to support a process underway for the purpose of purification.

The steam generator supplied was equipped with an exhaust gas bypass. This allows the engines to continue producing electricity even when no steam is extracted. There is also the advantage that with any impermissible rise in pressure, it is not necessary for the engine to be switched off by the mandatory safety chain.


One special feature of this project was the additional supply of a high-speed steam generator. This ensures that the required quantity of steam of 1,000 kg/h is always available.

As the water quality necessary for operation of the steam generator could not be supplied by the client, the water treatment system needed here was provided by APROVIS. This water treatment system consists of the following individual components:

  • Fine filter
  • Sodium ion exchanger
  • Reverse osmosis
  • Condensate collection tank
  • Degasser


Latest News

25January2012

BioGas World 2012


...

Read more

16December2011

biogas fair


...

Read more

28October2011

AGRITECHNICA 2011


...

Read more

22July2011

Grand opening ceremony of new...

On 22nd July 2011 APROVIS Energy Systems GmbH held the grand opening ceremony for its new...

Read more

11January2011

20. BIOGAS - Annual Conference and...

We participate in Nuremberg

Read more

22June2009

Exhaust Gas Heat Recovery Units...

A project in Russia involved the use of exhaust gas heat recovery units with integrated...

Read more

09June2009

Steam Generator in Austria

This steam generator is operated at a waste water treatment plant in Austria. The exhaust...

Read more

05April2009

Exhaust Gas-Heated Steam...

The installation of exhaust gas-heated steam generators in cogeneration plants helps to...

Read more

11February2009

Gas Dehumidification incl....

Technical data:
Gas volume flow: 700 Nm³/h
Gas inlet temperature: 35°C...

Read more