05.04.2009

Exhaust Gas-Heated Steam Generation System with 13 MW Steam Output

The installation of exhaust gas-heated steam generators in cogeneration plants helps to reduce the primary energy demand as well as ultimately minimising operating costs while also cutting CO2 emissions.

The following example demonstrates the benefit of an engine-operated cogeneration plant with exhaust gas-heated steam generators.

With an engine output of approx. 30 MW, this plant based in South-East Europe delivers
approx. 19.5 t/h saturated steam at 6.5 bar gauge. Only the exhaust gas heat of the engines is used to generate the steam.

The resulting saturated steam is continuously employed for steel production at the nearby industrial park. Efficient exhaust gas heat recovery from the engines boosts the overall efficiency of the plant to over 80%. Compared with the separate generation of power and thermal energy, a primary energy saving of approx. 40% is thus achieved by reducing the consumption of fossil fuels.
According to the operator the plant saves some 185,000 tonnes CO2 equivalent each year, so allowing the company to sell emissions certificates.

Every steam generator at the plant is heated by two engines. Here the exhaust gas paths are kept completely separate to prevent the engines influencing each other. Should there be a reduced demand for steam, the steam output of each engine can be "switched off" by bypassing the steam generator.

The production of steam and communication with the engines is ensured by a control panel with the APROVIS Controlling System (ACS) for each steam generator.
A high level of boiler availability is also guaranteed by means of modem-based remote maintenance/diagnostics.


Latest News

25Gennaio2012

BioGas World 2012


...

Più avanti

16Dicembre2011

biogas fair


...

Più avanti

28Ottobre2011

AGRITECHNICA 2011


...

Più avanti

22Luglio2011

Grand opening ceremony of new...

On 22nd July 2011 APROVIS Energy Systems GmbH held the grand opening ceremony for its new...

Più avanti

11Gennaio2011

20. BIOGAS - Annual Conference and...

We participate in Nuremberg

Più avanti

11Gennaio2011

20. BIOGAS - Annual Conference and...

We participate in Nuremberg

Più avanti

22Giugno2009

Exhaust Gas Heat Recovery Units...

A project in Russia involved the use of exhaust gas heat recovery units with integrated...

Più avanti

22Giugno2009

Unità per lo sfruttamento termico...

Nel caso di un progetto in Russia, sono state installate unità per lo sfruttamento...

Più avanti

09Giugno2009

Generatore di vapore in Austria

Questo generatore di vapore viene utilizzato in un impianto di depurazione in Austria. Il...

Più avanti

09Giugno2009

Steam Generator in Austria

This steam generator is operated at a waste water treatment plant in Austria. The exhaust...

Più avanti

05Aprile2009

Exhaust Gas-Heated Steam...

The installation of exhaust gas-heated steam generators in cogeneration plants helps to...

Più avanti

05Aprile2009

Impianto di generazione del vapore...

L'installazione di impianti di generazione del vapore a gas di combustione in impianti di...

Più avanti

11Febbraio2009

Deumidificazione del gas con...

Dati tecnici:
Flusso del volume di gas: 700 Nm³.
Temperatura di ingresso del gas...

Più avanti

11Febbraio2009

Gas Dehumidification incl....

Technical data:
Gas volume flow: 700 Nm³/h
Gas inlet temperature: 35°C...

Più avanti