11.02.2009

Gas Dehumidification incl. Condensate Drainage in France

Technical data:

  • Gas volume flow: 700 Nm³/h
  • Gas inlet temperature: 35°C
  • Cooling to approx. 5°C
  • Relative humidity at outlet approx. 30%

Designed as FriCon for outdoor installation

In comparison with conventional systems, the cooling capacity is ensured by both an air-cooled liquid chiller and the process gas itself. This reduces the cooling demand, so cutting operating costs by 14%!


Special features:

One specification made by the customer was explosion-proofing of the entire plant. This is why the cold water set and gas cooling unit are spaced 3 m apart. The condensate produced is discharged to a collection tank. Explosion protection is provided for the condensate pump and 4-point level switch (pump on/off, high/low water alarm).
The provisions of French law were satisfied by CE marking for the entire system (subassembly).


Latest News

25Janeiro2012

BioGas World 2012


...

Adicional

16Dezembro2011

biogas fair


...

Adicional

28Outubro2011

AGRITECHNICA 2011


...

Adicional

22Julho2011

Grand opening ceremony of new...

On 22nd July 2011 APROVIS Energy Systems GmbH held the grand opening ceremony for its new...

Adicional

11Janeiro2011

20. BIOGAS - Annual Conference and...

We participate in Nuremberg

Adicional

11Janeiro2011

20. BIOGAS - Annual Conference and...

We participate in Nuremberg

Adicional

22Junho2009

Exhaust Gas Heat Recovery Units...

A project in Russia involved the use of exhaust gas heat recovery units with integrated...

Adicional

22Junho2009

Unidades de recuperação de calor...

Em um projeto na Rússia, foram instaladas unidades de recuperação de calor proveniente...

Adicional

09Junho2009

Geradores de vapor na Áustria

Este gerador de vapor está funcionando em uma estação de tratamento de águas...

Adicional

09Junho2009

Steam Generator in Austria

This steam generator is operated at a waste water treatment plant in Austria. The exhaust...

Adicional

05Abril2009

Exhaust Gas-Heated Steam...

The installation of exhaust gas-heated steam generators in cogeneration plants helps to...

Adicional

05Abril2009

Instalação geradora de vapor...

A instalação de geradores de vapor aquecidos por gases de escape em sistemas de...

Adicional

11Fevereiro2009

Sistema de desumidificação com...

Dados técnicos:
Débito volumétrico de gás: 700 Nm³.
Temperatura de entrada do...

Adicional

11Fevereiro2009

Gas Dehumidification incl....

Technical data:
Gas volume flow: 700 Nm³/h
Gas inlet temperature: 35°C...

Adicional